Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry. / Bornø, Andreas; Foged, Lene; van Hall, Gerrit.

I: Journal of Mass Spectrometry, Bind 49, Nr. 10, 2014, s. 980-8.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Bornø, A, Foged, L & van Hall, G 2014, 'Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry', Journal of Mass Spectrometry, bind 49, nr. 10, s. 980-8. https://doi.org/10.1002/jms.3407

APA

Bornø, A., Foged, L., & van Hall, G. (2014). Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry. Journal of Mass Spectrometry, 49(10), 980-8. https://doi.org/10.1002/jms.3407

Vancouver

Bornø A, Foged L, van Hall G. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry. Journal of Mass Spectrometry. 2014;49(10):980-8. https://doi.org/10.1002/jms.3407

Author

Bornø, Andreas ; Foged, Lene ; van Hall, Gerrit. / Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry. I: Journal of Mass Spectrometry. 2014 ; Bind 49, Nr. 10. s. 980-8.

Bibtex

@article{646ee5b39e4a4895a78466016eb6ddb0,
title = "Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry",
abstract = "The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D(2)]glucose, [U-(13) C(6)]glucose, and [1,1,2,3,3-D(5)]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2) = 0.9998 for [U-(13) C(6)]glucose and r(2) = 0.9996 for [U-(13) C(6), D(7)]glucose, and r(2) = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-(13) C(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies.",
author = "Andreas Born{\o} and Lene Foged and {van Hall}, Gerrit",
note = "Copyright {\textcopyright} 2014 John Wiley & Sons, Ltd.",
year = "2014",
doi = "10.1002/jms.3407",
language = "English",
volume = "49",
pages = "980--8",
journal = "Journal of Mass Spectrometry",
issn = "1076-5174",
publisher = "JohnWiley & Sons Ltd",
number = "10",

}

RIS

TY - JOUR

T1 - Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

AU - Bornø, Andreas

AU - Foged, Lene

AU - van Hall, Gerrit

N1 - Copyright © 2014 John Wiley & Sons, Ltd.

PY - 2014

Y1 - 2014

N2 - The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D(2)]glucose, [U-(13) C(6)]glucose, and [1,1,2,3,3-D(5)]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2) = 0.9998 for [U-(13) C(6)]glucose and r(2) = 0.9996 for [U-(13) C(6), D(7)]glucose, and r(2) = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-(13) C(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies.

AB - The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D(2)]glucose, [U-(13) C(6)]glucose, and [1,1,2,3,3-D(5)]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2) = 0.9998 for [U-(13) C(6)]glucose and r(2) = 0.9996 for [U-(13) C(6), D(7)]glucose, and r(2) = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-(13) C(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies.