Identification of the pylorus from the intraluminal pH profile. Validation of the method by comparing it with transpyloric potential difference and pressure profile
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Standard
Identification of the pylorus from the intraluminal pH profile. Validation of the method by comparing it with transpyloric potential difference and pressure profile. / Rosenkilde-Gram, B; Højgaard, L; Kraglund, K; Rune, S J.
I: Scandinavian Journal of Gastroenterology, Bind 25, Nr. 11, 11.1990, s. 1181-4.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Identification of the pylorus from the intraluminal pH profile. Validation of the method by comparing it with transpyloric potential difference and pressure profile
AU - Rosenkilde-Gram, B
AU - Højgaard, L
AU - Kraglund, K
AU - Rune, S J
PY - 1990/11
Y1 - 1990/11
N2 - In contrast to the steady low intragastric pH, the pH in the proximal duodenum shows wide, rapid, and frequent fluctuations. This change in pH pattern may be used to localize the pylorus and thereby ensure reproducible measurements of duodenal pH at a known and reproducible distance from the pylorus. To validate this method of localizing the pylorus, simultaneous measurements were performed of the transpyloric pH and potential difference (PD) profile and of the pH and pressure profile in 10 normal subjects. pH-metry and PD-metry localized the pylorus within the same 1.5 cm in 82% of 104 5-min periods, and pH-metry and manometry localized the pylorus within the same 5 cm in 72% of 77 10-min periods. This agreement and accuracy seem satisfactory for most studies of intraluminal pH in the duodenum and make reliable long-term ambulatory recording of duodenal pH possible without serial roentgenogram controls.
AB - In contrast to the steady low intragastric pH, the pH in the proximal duodenum shows wide, rapid, and frequent fluctuations. This change in pH pattern may be used to localize the pylorus and thereby ensure reproducible measurements of duodenal pH at a known and reproducible distance from the pylorus. To validate this method of localizing the pylorus, simultaneous measurements were performed of the transpyloric pH and potential difference (PD) profile and of the pH and pressure profile in 10 normal subjects. pH-metry and PD-metry localized the pylorus within the same 1.5 cm in 82% of 104 5-min periods, and pH-metry and manometry localized the pylorus within the same 5 cm in 72% of 77 10-min periods. This agreement and accuracy seem satisfactory for most studies of intraluminal pH in the duodenum and make reliable long-term ambulatory recording of duodenal pH possible without serial roentgenogram controls.
KW - Adult
KW - Duodenum
KW - Female
KW - Humans
KW - Hydrogen-Ion Concentration
KW - Intestinal Mucosa
KW - Male
KW - Manometry
KW - Membrane Potentials
KW - Middle Aged
KW - Pylorus
KW - Comparative Study
KW - Journal Article
KW - Research Support, Non-U.S. Gov't
M3 - Journal article
C2 - 2274739
VL - 25
SP - 1181
EP - 1184
JO - Scandinavian Journal of Gastroenterology
JF - Scandinavian Journal of Gastroenterology
SN - 0036-5521
IS - 11
ER -
ID: 165885223