Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis : A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI. / Krabbe, Simon; Møller, Jakob M; Hadsbjerg, Anna E F; Ewald, Anne; Hangaard, Stine; Pedersen, Susanne J; Østergaard, Mikkel.

I: Skeletal Radiology, 2024.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Krabbe, S, Møller, JM, Hadsbjerg, AEF, Ewald, A, Hangaard, S, Pedersen, SJ & Østergaard, M 2024, 'Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI', Skeletal Radiology. https://doi.org/10.1007/s00256-024-04669-5

APA

Krabbe, S., Møller, J. M., Hadsbjerg, A. E. F., Ewald, A., Hangaard, S., Pedersen, S. J., & Østergaard, M. (2024). Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI. Skeletal Radiology. https://doi.org/10.1007/s00256-024-04669-5

Vancouver

Krabbe S, Møller JM, Hadsbjerg AEF, Ewald A, Hangaard S, Pedersen SJ o.a. Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI. Skeletal Radiology. 2024. https://doi.org/10.1007/s00256-024-04669-5

Author

Krabbe, Simon ; Møller, Jakob M ; Hadsbjerg, Anna E F ; Ewald, Anne ; Hangaard, Stine ; Pedersen, Susanne J ; Østergaard, Mikkel. / Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis : A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI. I: Skeletal Radiology. 2024.

Bibtex

@article{cc6f0c54f52f43f7ba19c954b3fdda16,
title = "Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI",
abstract = "OBJECTIVES: To investigate the detection of erosion, sclerosis and ankylosis using 1 mm 3D T1-weighted spoiled gradient echo (T1w-GRE) MRI and 1 mm MRI-based synthetic CT (sCT), compared with conventional 4 mm T1w-TSE.MATERIALS AND METHODS: Prospective, cross-sectional study. Semi-coronal 4 mm T1w-TSE and axial T1w-GRE with 1.6 mm slice thickness and 0.8 mm spacing between overlapping slices were performed. The T1w-GRE images were processed into sCT images using a commercial deep learning algorithm, BoneMRI. Both were reconstructed into 1 mm semi-coronal images. T1w-TSE, T1w-GRE and sCT images were assessed independently by 3 expert and 4 non-expert readers for erosion, sclerosis and ankylosis. Cohen's kappa for inter-reader agreement, exact McNemar test for lesion frequencies and Wilcoxon signed-rank test for confidence in lesion detection were used.RESULTS: Nineteen patients with axial spondyloarthritis were evaluated. T1w-GRE increased inter-reader agreement for detecting erosion (kappa 0.42 vs 0.21 in non-experts), increased detection of erosion (57 vs 43 of 152 joint quadrants) and sclerosis (26 vs 17 of 152 joint quadrants) among experts, and increased reader confidence for scoring erosion and sclerosis. sCT increased inter-reader agreement for detecting sclerosis (kappa 0.69 vs 0.37 in experts) and ankylosis (0.71 vs 0.52 in non-experts), increased detection of sclerosis (34 vs 17 of 152 joint quadrants) and ankylosis (20 vs 13 of 76 joint halves) among experts, and increased reader confidence for scoring erosion, sclerosis and ankylosis.CONCLUSION: T1w-GRE and sCT increase sensitivity and reader confidence for the detection of erosion, sclerosis and ankylosis, compared with T1w-TSE.CLINICAL RELEVANCE STATEMENT: These methods improve the detection of sacroiliac joint structural lesions and might be a useful addition to SIJ MRI protocols both in routine clinical care and as structural outcome measures in clinical trials.",
author = "Simon Krabbe and M{\o}ller, {Jakob M} and Hadsbjerg, {Anna E F} and Anne Ewald and Stine Hangaard and Pedersen, {Susanne J} and Mikkel {\O}stergaard",
note = "{\textcopyright} 2024. The Author(s).",
year = "2024",
doi = "10.1007/s00256-024-04669-5",
language = "English",
journal = "Skeletal Radiology",
issn = "0364-2348",
publisher = "Springer",

}

RIS

TY - JOUR

T1 - Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis

T2 - A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI

AU - Krabbe, Simon

AU - Møller, Jakob M

AU - Hadsbjerg, Anna E F

AU - Ewald, Anne

AU - Hangaard, Stine

AU - Pedersen, Susanne J

AU - Østergaard, Mikkel

N1 - © 2024. The Author(s).

PY - 2024

Y1 - 2024

N2 - OBJECTIVES: To investigate the detection of erosion, sclerosis and ankylosis using 1 mm 3D T1-weighted spoiled gradient echo (T1w-GRE) MRI and 1 mm MRI-based synthetic CT (sCT), compared with conventional 4 mm T1w-TSE.MATERIALS AND METHODS: Prospective, cross-sectional study. Semi-coronal 4 mm T1w-TSE and axial T1w-GRE with 1.6 mm slice thickness and 0.8 mm spacing between overlapping slices were performed. The T1w-GRE images were processed into sCT images using a commercial deep learning algorithm, BoneMRI. Both were reconstructed into 1 mm semi-coronal images. T1w-TSE, T1w-GRE and sCT images were assessed independently by 3 expert and 4 non-expert readers for erosion, sclerosis and ankylosis. Cohen's kappa for inter-reader agreement, exact McNemar test for lesion frequencies and Wilcoxon signed-rank test for confidence in lesion detection were used.RESULTS: Nineteen patients with axial spondyloarthritis were evaluated. T1w-GRE increased inter-reader agreement for detecting erosion (kappa 0.42 vs 0.21 in non-experts), increased detection of erosion (57 vs 43 of 152 joint quadrants) and sclerosis (26 vs 17 of 152 joint quadrants) among experts, and increased reader confidence for scoring erosion and sclerosis. sCT increased inter-reader agreement for detecting sclerosis (kappa 0.69 vs 0.37 in experts) and ankylosis (0.71 vs 0.52 in non-experts), increased detection of sclerosis (34 vs 17 of 152 joint quadrants) and ankylosis (20 vs 13 of 76 joint halves) among experts, and increased reader confidence for scoring erosion, sclerosis and ankylosis.CONCLUSION: T1w-GRE and sCT increase sensitivity and reader confidence for the detection of erosion, sclerosis and ankylosis, compared with T1w-TSE.CLINICAL RELEVANCE STATEMENT: These methods improve the detection of sacroiliac joint structural lesions and might be a useful addition to SIJ MRI protocols both in routine clinical care and as structural outcome measures in clinical trials.

AB - OBJECTIVES: To investigate the detection of erosion, sclerosis and ankylosis using 1 mm 3D T1-weighted spoiled gradient echo (T1w-GRE) MRI and 1 mm MRI-based synthetic CT (sCT), compared with conventional 4 mm T1w-TSE.MATERIALS AND METHODS: Prospective, cross-sectional study. Semi-coronal 4 mm T1w-TSE and axial T1w-GRE with 1.6 mm slice thickness and 0.8 mm spacing between overlapping slices were performed. The T1w-GRE images were processed into sCT images using a commercial deep learning algorithm, BoneMRI. Both were reconstructed into 1 mm semi-coronal images. T1w-TSE, T1w-GRE and sCT images were assessed independently by 3 expert and 4 non-expert readers for erosion, sclerosis and ankylosis. Cohen's kappa for inter-reader agreement, exact McNemar test for lesion frequencies and Wilcoxon signed-rank test for confidence in lesion detection were used.RESULTS: Nineteen patients with axial spondyloarthritis were evaluated. T1w-GRE increased inter-reader agreement for detecting erosion (kappa 0.42 vs 0.21 in non-experts), increased detection of erosion (57 vs 43 of 152 joint quadrants) and sclerosis (26 vs 17 of 152 joint quadrants) among experts, and increased reader confidence for scoring erosion and sclerosis. sCT increased inter-reader agreement for detecting sclerosis (kappa 0.69 vs 0.37 in experts) and ankylosis (0.71 vs 0.52 in non-experts), increased detection of sclerosis (34 vs 17 of 152 joint quadrants) and ankylosis (20 vs 13 of 76 joint halves) among experts, and increased reader confidence for scoring erosion, sclerosis and ankylosis.CONCLUSION: T1w-GRE and sCT increase sensitivity and reader confidence for the detection of erosion, sclerosis and ankylosis, compared with T1w-TSE.CLINICAL RELEVANCE STATEMENT: These methods improve the detection of sacroiliac joint structural lesions and might be a useful addition to SIJ MRI protocols both in routine clinical care and as structural outcome measures in clinical trials.

U2 - 10.1007/s00256-024-04669-5

DO - 10.1007/s00256-024-04669-5

M3 - Journal article

C2 - 38592521

JO - Skeletal Radiology

JF - Skeletal Radiology

SN - 0364-2348

ER -