Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor. / Hjortdal, V E; Timmenga, E J; Kjølseth, D; Brink Henriksen, T; Stender Hansen, E; Djurhuus, J C; Gottrup, F.

I: Annales Chirurgiae et Gynaecologiae. Supplementum, Bind 80, Nr. 1, 1991, s. 8-13.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Hjortdal, VE, Timmenga, EJ, Kjølseth, D, Brink Henriksen, T, Stender Hansen, E, Djurhuus, JC & Gottrup, F 1991, 'Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor', Annales Chirurgiae et Gynaecologiae. Supplementum, bind 80, nr. 1, s. 8-13.

APA

Hjortdal, V. E., Timmenga, E. J., Kjølseth, D., Brink Henriksen, T., Stender Hansen, E., Djurhuus, J. C., & Gottrup, F. (1991). Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor. Annales Chirurgiae et Gynaecologiae. Supplementum, 80(1), 8-13.

Vancouver

Hjortdal VE, Timmenga EJ, Kjølseth D, Brink Henriksen T, Stender Hansen E, Djurhuus JC o.a. Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor. Annales Chirurgiae et Gynaecologiae. Supplementum. 1991;80(1):8-13.

Author

Hjortdal, V E ; Timmenga, E J ; Kjølseth, D ; Brink Henriksen, T ; Stender Hansen, E ; Djurhuus, J C ; Gottrup, F. / Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor. I: Annales Chirurgiae et Gynaecologiae. Supplementum. 1991 ; Bind 80, Nr. 1. s. 8-13.

Bibtex

@article{19842cabb36e40bbb2756ec31b40657b,
title = "Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor",
abstract = "An oxygen tension measurement equipment, developed for continuous intravascular monitoring was tested as a direct tissue oxygen tension meter. The sterile disposable oxygen probe consists of a Clark type polaro-graphic bipolar electrode placed in a 5 cm long flexible polyethylene catheter (OD 0.55 mm). The probe is easily placed, e.g. in subcutaneous tissue or muscle, with the aid of an introduction needle. In vitro measurements as well as subcutaneous and intramuscular readings were performed. The animals were subjected to various experimental conditions such as different inspiratory oxygen fractions, hypovolemia, and circulatory impairment. Results were comparable to those obtained with previously used and well characterized tissue oxygen tension measurement equipment. The clinical applicability of the oxygen sensor for tissue oxygen measurement was assessed in one patient by 40 hours' surveillance in a free myocutaneous flap. The procedure was simple and implied minimal discomfort for the patient.",
keywords = "Animals, Electrodes, Humans, In Vitro Techniques, Monitoring, Physiologic/instrumentation, Oxygen/analysis, Swine",
author = "Hjortdal, {V E} and Timmenga, {E J} and D Kj{\o}lseth and {Brink Henriksen}, T and {Stender Hansen}, E and Djurhuus, {J C} and F Gottrup",
year = "1991",
language = "English",
volume = "80",
pages = "8--13",
journal = "Annales Chirurgiae et Gynaecologiae",
issn = "0355-9874",
publisher = "Finnish Medical Society Duodecim",
number = "1",

}

RIS

TY - JOUR

T1 - Continuous direct tissue oxygen tension measurement. A new application for an intravascular oxygen sensor

AU - Hjortdal, V E

AU - Timmenga, E J

AU - Kjølseth, D

AU - Brink Henriksen, T

AU - Stender Hansen, E

AU - Djurhuus, J C

AU - Gottrup, F

PY - 1991

Y1 - 1991

N2 - An oxygen tension measurement equipment, developed for continuous intravascular monitoring was tested as a direct tissue oxygen tension meter. The sterile disposable oxygen probe consists of a Clark type polaro-graphic bipolar electrode placed in a 5 cm long flexible polyethylene catheter (OD 0.55 mm). The probe is easily placed, e.g. in subcutaneous tissue or muscle, with the aid of an introduction needle. In vitro measurements as well as subcutaneous and intramuscular readings were performed. The animals were subjected to various experimental conditions such as different inspiratory oxygen fractions, hypovolemia, and circulatory impairment. Results were comparable to those obtained with previously used and well characterized tissue oxygen tension measurement equipment. The clinical applicability of the oxygen sensor for tissue oxygen measurement was assessed in one patient by 40 hours' surveillance in a free myocutaneous flap. The procedure was simple and implied minimal discomfort for the patient.

AB - An oxygen tension measurement equipment, developed for continuous intravascular monitoring was tested as a direct tissue oxygen tension meter. The sterile disposable oxygen probe consists of a Clark type polaro-graphic bipolar electrode placed in a 5 cm long flexible polyethylene catheter (OD 0.55 mm). The probe is easily placed, e.g. in subcutaneous tissue or muscle, with the aid of an introduction needle. In vitro measurements as well as subcutaneous and intramuscular readings were performed. The animals were subjected to various experimental conditions such as different inspiratory oxygen fractions, hypovolemia, and circulatory impairment. Results were comparable to those obtained with previously used and well characterized tissue oxygen tension measurement equipment. The clinical applicability of the oxygen sensor for tissue oxygen measurement was assessed in one patient by 40 hours' surveillance in a free myocutaneous flap. The procedure was simple and implied minimal discomfort for the patient.

KW - Animals

KW - Electrodes

KW - Humans

KW - In Vitro Techniques

KW - Monitoring, Physiologic/instrumentation

KW - Oxygen/analysis

KW - Swine

M3 - Journal article

C2 - 1888120

VL - 80

SP - 8

EP - 13

JO - Annales Chirurgiae et Gynaecologiae

JF - Annales Chirurgiae et Gynaecologiae

SN - 0355-9874

IS - 1

ER -

ID: 244328617