Strain Imaging and Ventricular Arrhythmia

Research output: Contribution to journalReviewResearchpeer-review

Standard

Strain Imaging and Ventricular Arrhythmia. / Bjerregaard, Caroline Løkke; Skaarup, Kristoffer Grundtvig; Lassen, Mats Christian Højbjerg; Biering-Sørensen, Tor; Olsen, Flemming Javier.

In: Diagnostics, Vol. 13, No. 10, 1778, 2023.

Research output: Contribution to journalReviewResearchpeer-review

Harvard

Bjerregaard, CL, Skaarup, KG, Lassen, MCH, Biering-Sørensen, T & Olsen, FJ 2023, 'Strain Imaging and Ventricular Arrhythmia', Diagnostics, vol. 13, no. 10, 1778. https://doi.org/10.3390/diagnostics13101778

APA

Bjerregaard, C. L., Skaarup, K. G., Lassen, M. C. H., Biering-Sørensen, T., & Olsen, F. J. (2023). Strain Imaging and Ventricular Arrhythmia. Diagnostics, 13(10), [1778]. https://doi.org/10.3390/diagnostics13101778

Vancouver

Bjerregaard CL, Skaarup KG, Lassen MCH, Biering-Sørensen T, Olsen FJ. Strain Imaging and Ventricular Arrhythmia. Diagnostics. 2023;13(10). 1778. https://doi.org/10.3390/diagnostics13101778

Author

Bjerregaard, Caroline Løkke ; Skaarup, Kristoffer Grundtvig ; Lassen, Mats Christian Højbjerg ; Biering-Sørensen, Tor ; Olsen, Flemming Javier. / Strain Imaging and Ventricular Arrhythmia. In: Diagnostics. 2023 ; Vol. 13, No. 10.

Bibtex

@article{ab83bfe6a1d24513bf7714dd11fdc202,
title = "Strain Imaging and Ventricular Arrhythmia",
abstract = "Ventricular arrhythmia is one of the main causes of sudden cardiac death. Hence, identifying patients at risk of ventricular arrhythmias and sudden cardiac death is important but can be challenging. The indication for an implantable cardioverter defibrillator as a primary preventive strategy relies on the left ventricular ejection fraction as a measure of systolic function. However, ejection fraction is flawed by technical constraints and is an indirect measure of systolic function. There has, therefore, been an incentive to identify other markers to optimize the risk prediction of malignant arrhythmias to select proper candidates who could benefit from an implantable cardioverter defibrillator. Speckle-tracking echocardiography allows for a detailed assessment of cardiac mechanics, and strain imaging has repeatedly been shown to be a sensitive technique to identify systolic dysfunction unrecognized by ejection fraction. Several strain measures, including global longitudinal strain, regional strain, and mechanical dispersion, have consequently been proposed as potential markers of ventricular arrhythmias. In this review, we will provide an overview of the potential use of different strain measures in the context of ventricular arrhythmias.",
keywords = "arrhythmia, dyssynchrony, mechanical dispersion, myocardial work, strain",
author = "Bjerregaard, {Caroline L{\o}kke} and Skaarup, {Kristoffer Grundtvig} and Lassen, {Mats Christian H{\o}jbjerg} and Tor Biering-S{\o}rensen and Olsen, {Flemming Javier}",
note = "Publisher Copyright: {\textcopyright} 2023 by the authors.",
year = "2023",
doi = "10.3390/diagnostics13101778",
language = "English",
volume = "13",
journal = "Diagnostics",
issn = "2075-4418",
publisher = "MDPI AG",
number = "10",

}

RIS

TY - JOUR

T1 - Strain Imaging and Ventricular Arrhythmia

AU - Bjerregaard, Caroline Løkke

AU - Skaarup, Kristoffer Grundtvig

AU - Lassen, Mats Christian Højbjerg

AU - Biering-Sørensen, Tor

AU - Olsen, Flemming Javier

N1 - Publisher Copyright: © 2023 by the authors.

PY - 2023

Y1 - 2023

N2 - Ventricular arrhythmia is one of the main causes of sudden cardiac death. Hence, identifying patients at risk of ventricular arrhythmias and sudden cardiac death is important but can be challenging. The indication for an implantable cardioverter defibrillator as a primary preventive strategy relies on the left ventricular ejection fraction as a measure of systolic function. However, ejection fraction is flawed by technical constraints and is an indirect measure of systolic function. There has, therefore, been an incentive to identify other markers to optimize the risk prediction of malignant arrhythmias to select proper candidates who could benefit from an implantable cardioverter defibrillator. Speckle-tracking echocardiography allows for a detailed assessment of cardiac mechanics, and strain imaging has repeatedly been shown to be a sensitive technique to identify systolic dysfunction unrecognized by ejection fraction. Several strain measures, including global longitudinal strain, regional strain, and mechanical dispersion, have consequently been proposed as potential markers of ventricular arrhythmias. In this review, we will provide an overview of the potential use of different strain measures in the context of ventricular arrhythmias.

AB - Ventricular arrhythmia is one of the main causes of sudden cardiac death. Hence, identifying patients at risk of ventricular arrhythmias and sudden cardiac death is important but can be challenging. The indication for an implantable cardioverter defibrillator as a primary preventive strategy relies on the left ventricular ejection fraction as a measure of systolic function. However, ejection fraction is flawed by technical constraints and is an indirect measure of systolic function. There has, therefore, been an incentive to identify other markers to optimize the risk prediction of malignant arrhythmias to select proper candidates who could benefit from an implantable cardioverter defibrillator. Speckle-tracking echocardiography allows for a detailed assessment of cardiac mechanics, and strain imaging has repeatedly been shown to be a sensitive technique to identify systolic dysfunction unrecognized by ejection fraction. Several strain measures, including global longitudinal strain, regional strain, and mechanical dispersion, have consequently been proposed as potential markers of ventricular arrhythmias. In this review, we will provide an overview of the potential use of different strain measures in the context of ventricular arrhythmias.

KW - arrhythmia

KW - dyssynchrony

KW - mechanical dispersion

KW - myocardial work

KW - strain

UR - http://www.scopus.com/inward/record.url?scp=85160573141&partnerID=8YFLogxK

U2 - 10.3390/diagnostics13101778

DO - 10.3390/diagnostics13101778

M3 - Review

C2 - 37238262

AN - SCOPUS:85160573141

VL - 13

JO - Diagnostics

JF - Diagnostics

SN - 2075-4418

IS - 10

M1 - 1778

ER -

ID: 353759459