Treatment of Severe Bone Defects During Revision Total Knee Arthroplasty with Structural Allografts and Porous Metal Cones: A Systematic Review

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

  • Nicholas A Beckmann
  • Sebastian Mueller
  • Gondan, Matthias
  • Sebastian Jaeger
  • Tobias Reiner
  • Rudi G Bitsch

Aseptic loosening and focal osteolysis are the most common reasons for knee arthroplasty failure. The best treatment remains unclear. We reviewed the literature on the treatment of revision knee arthroplasty using bony structural allografts (476 cases) and porous metal cones (223 cases) to determine if a difference in the revision failure rates was discernable. The failure rates were compared using a logistic regression model with adjustment for discrepancies in FU time and number of grafts used (femoral, tibial, or both). In this analysis, the porous implant shows a significantly decreased loosening rate in AORI 2 and 3 defects. The overall failure rate was also substantially lower in the porous metal group than the structural allograft group; little difference in the infection rates was noted.

OriginalsprogEngelsk
TidsskriftJournal of Arthroplasty
Vol/bind30
Udgave nummer2
Sider (fra-til)249–253
Antal sider5
ISSN0883-5403
DOI
StatusUdgivet - 2015