Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Standard

Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt. / Højgaard, Michael V; Agner, Erik; Kanters, Jørgen K; Holstein-Rathlou, N.-H.

I: Blood Pressure Monitoring, Bind 10, Nr. 1, 2005, s. 19-24.

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Harvard

Højgaard, MV, Agner, E, Kanters, JK & Holstein-Rathlou, N-H 2005, 'Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.', Blood Pressure Monitoring, bind 10, nr. 1, s. 19-24.

APA

Højgaard, M. V., Agner, E., Kanters, J. K., & Holstein-Rathlou, N-H. (2005). Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt. Blood Pressure Monitoring, 10(1), 19-24.

Vancouver

Højgaard MV, Agner E, Kanters JK, Holstein-Rathlou N-H. Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt. Blood Pressure Monitoring. 2005;10(1):19-24.

Author

Højgaard, Michael V ; Agner, Erik ; Kanters, Jørgen K ; Holstein-Rathlou, N.-H. / Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt. I: Blood Pressure Monitoring. 2005 ; Bind 10, Nr. 1. s. 19-24.

Bibtex

@article{8417df30ab6011ddb5e9000ea68e967b,
title = "Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.",
abstract = "OBJECTIVE: Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS: We measured normal-to-normal heart beat (RR) interval and finger blood pressure (Finapres) in 14 healthy individuals on three different days. The protocol was 1 h of supine rest and 1 h of 60-degree head-up tilt. Time-series of consecutive 300-s segments as well as 1024-s segments of RR intervals and systolic, diastolic and mean blood pressures were extracted for the assessment of day-to-day and short-term reproducibility. Power spectrum analysis (Fourier) and transfer function analysis was performed. Reproducibility was assessed using the coefficient of variation (CV). The reproducibility of the mean RR interval, mean systolic, diastolic and mean blood pressure was good (CV<10 %). However, there was only moderate-to-poor reproducibility of the spectral parameters of HRV (CV range 18-36%) and BPV (16-44%) and moderate reproducibility of BRS (14-20%). CONCLUSION: Spectral estimates of BRS had only moderate reproducibility although it was better than the spectral estimates of HRV and BPV.",
author = "H{\o}jgaard, {Michael V} and Erik Agner and Kanters, {J{\o}rgen K} and N.-H. Holstein-Rathlou",
note = "Keywords: Adult; Baroreflex; Blood Pressure; Heart Rate; Humans; Posture; Reference Values; Reproducibility of Results; Rest; Statistical Distributions",
year = "2005",
language = "English",
volume = "10",
pages = "19--24",
journal = "Blood Pressure Monitoring",
issn = "1359-5237",
publisher = "Lippincott Williams & Wilkins",
number = "1",

}

RIS

TY - JOUR

T1 - Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

AU - Højgaard, Michael V

AU - Agner, Erik

AU - Kanters, Jørgen K

AU - Holstein-Rathlou, N.-H.

N1 - Keywords: Adult; Baroreflex; Blood Pressure; Heart Rate; Humans; Posture; Reference Values; Reproducibility of Results; Rest; Statistical Distributions

PY - 2005

Y1 - 2005

N2 - OBJECTIVE: Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS: We measured normal-to-normal heart beat (RR) interval and finger blood pressure (Finapres) in 14 healthy individuals on three different days. The protocol was 1 h of supine rest and 1 h of 60-degree head-up tilt. Time-series of consecutive 300-s segments as well as 1024-s segments of RR intervals and systolic, diastolic and mean blood pressures were extracted for the assessment of day-to-day and short-term reproducibility. Power spectrum analysis (Fourier) and transfer function analysis was performed. Reproducibility was assessed using the coefficient of variation (CV). The reproducibility of the mean RR interval, mean systolic, diastolic and mean blood pressure was good (CV<10 %). However, there was only moderate-to-poor reproducibility of the spectral parameters of HRV (CV range 18-36%) and BPV (16-44%) and moderate reproducibility of BRS (14-20%). CONCLUSION: Spectral estimates of BRS had only moderate reproducibility although it was better than the spectral estimates of HRV and BPV.

AB - OBJECTIVE: Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS: We measured normal-to-normal heart beat (RR) interval and finger blood pressure (Finapres) in 14 healthy individuals on three different days. The protocol was 1 h of supine rest and 1 h of 60-degree head-up tilt. Time-series of consecutive 300-s segments as well as 1024-s segments of RR intervals and systolic, diastolic and mean blood pressures were extracted for the assessment of day-to-day and short-term reproducibility. Power spectrum analysis (Fourier) and transfer function analysis was performed. Reproducibility was assessed using the coefficient of variation (CV). The reproducibility of the mean RR interval, mean systolic, diastolic and mean blood pressure was good (CV<10 %). However, there was only moderate-to-poor reproducibility of the spectral parameters of HRV (CV range 18-36%) and BPV (16-44%) and moderate reproducibility of BRS (14-20%). CONCLUSION: Spectral estimates of BRS had only moderate reproducibility although it was better than the spectral estimates of HRV and BPV.

M3 - Journal article

C2 - 15687870

VL - 10

SP - 19

EP - 24

JO - Blood Pressure Monitoring

JF - Blood Pressure Monitoring

SN - 1359-5237

IS - 1

ER -

ID: 8420061