A maximal cycle test with good validity and high repeatability in adults of all ages

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Standard

A maximal cycle test with good validity and high repeatability in adults of all ages. / Eriksen, L; Tolstrup, J S; Larsen, Steen; Grønbæk, M; Helge, Jørn Wulff.

I: International Journal of Sports Medicine, Bind 35, Nr. 14, 12.2014, s. 1184-9.

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Harvard

Eriksen, L, Tolstrup, JS, Larsen, S, Grønbæk, M & Helge, JW 2014, 'A maximal cycle test with good validity and high repeatability in adults of all ages', International Journal of Sports Medicine, bind 35, nr. 14, s. 1184-9. https://doi.org/10.1055/s-0034-1376973

APA

Eriksen, L., Tolstrup, J. S., Larsen, S., Grønbæk, M., & Helge, J. W. (2014). A maximal cycle test with good validity and high repeatability in adults of all ages. International Journal of Sports Medicine, 35(14), 1184-9. https://doi.org/10.1055/s-0034-1376973

Vancouver

Eriksen L, Tolstrup JS, Larsen S, Grønbæk M, Helge JW. A maximal cycle test with good validity and high repeatability in adults of all ages. International Journal of Sports Medicine. 2014 dec.;35(14):1184-9. https://doi.org/10.1055/s-0034-1376973

Author

Eriksen, L ; Tolstrup, J S ; Larsen, Steen ; Grønbæk, M ; Helge, Jørn Wulff. / A maximal cycle test with good validity and high repeatability in adults of all ages. I: International Journal of Sports Medicine. 2014 ; Bind 35, Nr. 14. s. 1184-9.

Bibtex

@article{879caf3bfe094b2cbd369acf228906e4,
title = "A maximal cycle test with good validity and high repeatability in adults of all ages",
abstract = "In 11 680 individuals (18-85 years) maximal oxygen consumption (VO2max) was estimated indirectly in a maximal cycle test using a prediction model developed in a young population (15-28 years). A subsample of 182 individuals (23-77 years) underwent 2 maximal cycle tests with VO2max estimated indirectly in both tests and measured directly in one test. Agreement between the direct measurement and the indirect estimate of VO2max and repeatability of the indirect estimates of VO2max were examined by Bland-Altman plots, limits of agreement (LOA) and coefficient of repeatability (CR). The indirect method (mean VO2max=3 132 ml · min(-1)) underestimated VO2max as compared to the direct method (mean VO2max=3 190 ml · min(-1)) in men (bias: 58 ml · min(-1) (95% LOA-450 and 565)) and overestimated VO2max in women (mean VO2max=2 328 vs. 2 258 ml · min(-1), bias: - 70 ml · min(-1) (95% LOA-468 and 328)). The mean difference between the 2 indirect estimates was non-significant (men: - 11.9 ml · min(-1), women: 18.3 ml · min(-1)) with a CR of 279 ml · min(-1) (8.9%) in men and 274 ml · min(-1) (11.7%) in women. The validity of the indirect method was good despite minor sex-specific bias. Owing to this bias we suggest a new prediction model of VO2max. The maximal cycle test was highly repeatable.",
author = "L Eriksen and Tolstrup, {J S} and Steen Larsen and M Gr{\o}nb{\ae}k and Helge, {J{\o}rn Wulff}",
note = "{\textcopyright} Georg Thieme Verlag KG Stuttgart · New York.",
year = "2014",
month = dec,
doi = "10.1055/s-0034-1376973",
language = "English",
volume = "35",
pages = "1184--9",
journal = "International Journal of Sports Medicine",
issn = "0172-4622",
publisher = "GeorgThieme Verlag",
number = "14",

}

RIS

TY - JOUR

T1 - A maximal cycle test with good validity and high repeatability in adults of all ages

AU - Eriksen, L

AU - Tolstrup, J S

AU - Larsen, Steen

AU - Grønbæk, M

AU - Helge, Jørn Wulff

N1 - © Georg Thieme Verlag KG Stuttgart · New York.

PY - 2014/12

Y1 - 2014/12

N2 - In 11 680 individuals (18-85 years) maximal oxygen consumption (VO2max) was estimated indirectly in a maximal cycle test using a prediction model developed in a young population (15-28 years). A subsample of 182 individuals (23-77 years) underwent 2 maximal cycle tests with VO2max estimated indirectly in both tests and measured directly in one test. Agreement between the direct measurement and the indirect estimate of VO2max and repeatability of the indirect estimates of VO2max were examined by Bland-Altman plots, limits of agreement (LOA) and coefficient of repeatability (CR). The indirect method (mean VO2max=3 132 ml · min(-1)) underestimated VO2max as compared to the direct method (mean VO2max=3 190 ml · min(-1)) in men (bias: 58 ml · min(-1) (95% LOA-450 and 565)) and overestimated VO2max in women (mean VO2max=2 328 vs. 2 258 ml · min(-1), bias: - 70 ml · min(-1) (95% LOA-468 and 328)). The mean difference between the 2 indirect estimates was non-significant (men: - 11.9 ml · min(-1), women: 18.3 ml · min(-1)) with a CR of 279 ml · min(-1) (8.9%) in men and 274 ml · min(-1) (11.7%) in women. The validity of the indirect method was good despite minor sex-specific bias. Owing to this bias we suggest a new prediction model of VO2max. The maximal cycle test was highly repeatable.

AB - In 11 680 individuals (18-85 years) maximal oxygen consumption (VO2max) was estimated indirectly in a maximal cycle test using a prediction model developed in a young population (15-28 years). A subsample of 182 individuals (23-77 years) underwent 2 maximal cycle tests with VO2max estimated indirectly in both tests and measured directly in one test. Agreement between the direct measurement and the indirect estimate of VO2max and repeatability of the indirect estimates of VO2max were examined by Bland-Altman plots, limits of agreement (LOA) and coefficient of repeatability (CR). The indirect method (mean VO2max=3 132 ml · min(-1)) underestimated VO2max as compared to the direct method (mean VO2max=3 190 ml · min(-1)) in men (bias: 58 ml · min(-1) (95% LOA-450 and 565)) and overestimated VO2max in women (mean VO2max=2 328 vs. 2 258 ml · min(-1), bias: - 70 ml · min(-1) (95% LOA-468 and 328)). The mean difference between the 2 indirect estimates was non-significant (men: - 11.9 ml · min(-1), women: 18.3 ml · min(-1)) with a CR of 279 ml · min(-1) (8.9%) in men and 274 ml · min(-1) (11.7%) in women. The validity of the indirect method was good despite minor sex-specific bias. Owing to this bias we suggest a new prediction model of VO2max. The maximal cycle test was highly repeatable.

U2 - 10.1055/s-0034-1376973

DO - 10.1055/s-0034-1376973

M3 - Journal article

C2 - 25259589

VL - 35

SP - 1184

EP - 1189

JO - International Journal of Sports Medicine

JF - International Journal of Sports Medicine

SN - 0172-4622

IS - 14

ER -

ID: 132011295